Altera Home Page
文档资料 许可
在线购买 下载

  主页   |   产品   |   支持   |   最终市场   |   技术中心   |   教育与活动   |   公司介绍   |   在线购买  
  mySupport   |   器件   |   软件   |   IP   |   设计范例   |   参考设计  

 FPGA
      Stratix IV(E和GX)
      Stratix III
      Stratix II/Stratix II GX
      Stratix/Stratix GX
      Arria GX
      Cyclone III
      Cyclone II
      Cyclone
  
 CPLD
      MAX II
      MAX 3000A
      MAX 7000
  
 ASIC
      HardCopy III
      HardCopy II
      HardCopy Stratix
      HardCopy APEX 20K
  
 下载
      器件管脚列表
      Gerber Files
      IBIS模型
   BSDL/BST
      PCB符号
  
 配置/编程
   配置
   编程
   编程工具
  
 功耗
   功耗管理
      早期功耗估算器
      认证的电源解决方案
  
 I/O
      I/O规格
      特性
      热插拔
  
 PLL与时钟管理
      概要
      PLL基础
      在软件中使用PLL
      Jitter信息
      时钟网络
      术语
  
 封装和板级设计
      封装规格
      热阻
      布局/Socket
      制造
  
 质量与可靠性
      MSL 计算器
      认证
   环境
      PCN & Advisories
   报告
  
 失效分析
      概要
      失效分析能力
  

Failure Analysis Capabilities

Altera uses state-of-the-art equipment for failure analysis. Depending on the type of failure reported, Altera can perform various tests to resolve the issues, including: full functional and timing tests; C-mode scanning acoustic microscopy (C­SAM); scanning electron microscopy; emission microscopy; x-ray, and liquid crystal testing.

The C­SAM test is a non­destructive check for device delamination (shown in Figure 1). Improper solder reflow techniques or improper handling of moisture-sensitive devices can cause delamination, which is separation of the die from the molding compound. More information is available in AN 81: Reflow Soldering Guidelines for Surface­Mount Devices (PDF).

Figure 1. Device with Delamination

Figure 1. Device with Delamination

Emission microscopy (shown in Figure 1) can isolate the failure's specific location. This test loads the device with test vectors to verify all the device's routing paths. An emission microscope can detect excessive current and pinpoint damaged circuitry. Figure 2 shows the results of an emission microscope test; high current leakage is normally shown in red, but here the location is shown with arrows.

Figure 2. Emmission Microscope Shows Leakage on Pins 19 & 20

Figure 2. Emmission Microscope Shows Leakage on Pins 19 & 20

Altera can also use a scanning electron microscope (SEM) to analyze a device. In Figure 3, the SEM test found spiking under metal caused by electrical overstress.

Figure 3. SEM Test Shows Spiking

Figure 3. SEM Test Shows Spiking

  请填写反馈意见
  注册索取最新邮件通知