Altera Home Page
文档资料 许可
在线购买 下载

  主页   |   产品   |   支持   |   最终市场   |   技术中心   |   教育与活动   |   公司介绍   |   在线购买  
  mySupport   |   器件   |   软件   |   IP   |   设计范例   |   参考设计  

 产品
      MAX/MAX II
      Stratix/Stratix GX
      Nios II
  
 功能
      算法
      存储器
      总线及I/O
      逻辑
      接口与外设
      DSP
      通信
      PLL & Clocking
  
 设计输入方法
      Quartus II软件工程
      Tcl
      VHDL
      Verilog HDL
      C Code 范例
      DSP Builder
      TimeQuest
   片内调试
  
 仿真工具
      Mentor Graphics ModelSim
      Cadence NCsim
      Synopsys VCS
  
 旧范例
      图形编辑器
      AHDL
  

Quartus II Design Examples: Examples for altremote_update Megafunction

The altremote_update Megafunction User Guide provides two design examples to illustrate parameter writing along with reconfiguration and parameter reading using the altremote_update megafunction. These two design examples use the MegaWizard® Plug-In Manager in the Quartus® II software. The steps to generate the megafunction using the MegaWizard Plug-In Manager are described in detail in the User Guide.

Design Example 1: Parameter Writes and reconfig

This design example illustrates the sequence of control signals to be applied to set the time out value of the watchdog timer to any required count and enable the same. It also illustrates the sequence to select an application page and apply reconfig to start reconfiguration of the device to the selected page. 

In this example, you do the following:

  • Instantiate remote update block using the altremote_update megafunction and the MegaWizard Plug-in Manager.
  • Implement the design and assign the EP1S10B672C6 device to the project
  • Compile and simulate the design

The following design files are used in this example:

  1. The Quartus II project archive
  2. README file

The use of this design is governed by, and subject to, the terms and conditions of the Altera Hardware Reference Design License Agreement.

Design Example 2: Parameter Read

This design example illustrates the sequence of control signals to be applied to read the watchdog enable status, watchdog timeout value, the page set for reconfiguration and the current configuration state.

In this example, you do the following.

  • Instantiate remote update block using the altremote_update megafunction and the MegaWizard Plug-in Manager
  • Implement the design and assign the EP1S25F1020C5 device to the project
  • Compile and simulate the design

Design Files: The following files are used in this example.

  1. The Quartus II project archive 
  2. README file

The use of this design is governed by, and subject to, the terms and conditions of the Altera Hardware Reference Design License Agreement.

Design Examples Disclaimer

These design examples may only be used within Altera Corporation devices and remain the property of Altera. They are being provided on an “as-is” basis and as an accommodation; therefore, all warranties, representations, or guarantees of any kind (whether express, implied, or statutory) including, without limitation, warranties of merchantability, non-infringement, or fitness for a particular purpose, are specifically disclaimed. Altera expressly does not recommend, suggest, or require that these examples be used in combination with any other product not provided by Altera.

  请填写反馈意见