解决方案ID: rd05122004_1551
最后修改: 2010 年6 月21 日
产品类别: 器件
产品领域: 配置(FPGA)
产品子领域: 配置管脚
器件系列: STRATIX
标题
Is it acceptable to toggle the DATA and DCLK signals once a Stratix® or a Cyclone® device has entered user mode?
说明
DCLK and DATA0 are dedicated inputs that are used during configuration for Cyclone® devices. DATA[7:0] are dual purpose pins for Stratix® devices that can operate as a user defined pin in user mode depending on the dual purpose pin setting (device and pin options tab). So for a Stratix device, DCLK is a dedicated input and DATA[7:0] is a dual purpose pin. Once configuration is done and the Stratix and Cyclone device has entered into user mode, DCLK and DATA can be toggled without effecting the configuration data.反馈
Altera并不保证此解决方案能够达到客户的预期目的,并不承担所有的解决方案的使用和信赖的责任。